P548E Zone Group #18 Entry Delay - Default 0
P549E Zone Group #19 Entry Delay - Default 0
P550E Zone Group #20 Entry Delay - Default 0
ZONE GROUP DIALLING SCENARIO NUMBER
There are four dialling scenarios that can be programmed allowing the option of having different zones report to
different monitoring stations. Alternatively, you could have some zones report to a monitoring station and some plant
alarms report using voice messages to a technicians mobile telephone. A value of 0-4 can be entered in these fields.
A value of 0 means that the zone group will not report alarms via the dialler.
P551E Zone Group #1 Scenario # - Default 1
P552E Zone Group #2 Scenario # - Default 1
P553E Zone Group #3 Scenario # - Default 1
P554E Zone Group #4 Scenario # - Default 1
P555E Zone Group #5 Scenario # - Default 1
P556E Zone Group #6 Scenario # - Default 1
P557E Zone Group #7 Scenario # - Default 1
P558E Zone Group #8 Scenario # - Default 1
P559E Zone Group #9 Scenario # - Default 1
P560E Zone Group #10 Scenario # - Default 1
P561E Zone Group #11 Scenario # - Default 1
P562E Zone Group #12 Scenario # - Default 1
P563E Zone Group #13 Scenario # - Default 1
P564E Zone Group #14 Scenario # - Default 1
P565E Zone Group #15 Scenario # - Default 1
P566E Zone Group #16 Scenario # - Default 1
P567E Zone Group #17 Scenario # - Default 1
P568E Zone Group #18 Scenario # - Default 1
P569E Zone Group #19 Scenario # - Default 1
P570E Zone Group #20 Scenario # - Default 1
ZONE GROUP ALARM CONTACT ID REPORTING CODE
When a zone group reports an alarm to a monitoring station using Contact ID, the default event code is 130 for
“Burglar Alarm”. Should you require some zone groups to report alarms as Fire, Medical, Plant, etc, you can change
the event code transmitted using these addresses.
P571E Zone Group #1 Contact ID Alarm Code (Default = 130)
P572E Zone Group #2 Contact ID Alarm Code (Default = 130)
P573E Zone Group #3 Contact ID Alarm Code (Default = 130)
P574E Zone Group #4 Contact ID Alarm Code (Default = 130)
P575E Zone Group #5 Contact ID Alarm Code (Default = 130)
P576E Zone Group #6 Contact ID Alarm Code (Default = 130)
P577E Zone Group #7 Contact ID Alarm Code (Default = 130)
P578E Zone Group #8 Contact ID Alarm Code (Default = 130)
P579E Zone Group #9 Contact ID Alarm Code (Default = 130)
P580E Zone Group #10 Contact ID Alarm Code (Default = 130)
P581E Zone Group #11 Contact ID Alarm Code (Default = 130)
P582E Zone Group #12 Contact ID Alarm Code (Default = 130)
P583E Zone Group #13 Contact ID Alarm Code (Default = 130)
P584E Zone Group #14 Contact ID Alarm Code (Default = 130)
P585E Zone Group #15 Contact ID Alarm Code (Default = 130)
P586E Zone Group #16 Contact ID Alarm Code (Default = 130)
P587E Zone Group #17 Contact ID Alarm Code (Default = 130)
P588E Zone Group #18 Contact ID Alarm Code (Default = 130)
P589E Zone Group #19 Contact ID Alarm Code (Default = 130)
P590E Zone Group #20 Contact ID Alarm Code (Default = 130)
ZONE GROUP CONTACT ID TAMPER REPORTING CODE
When a zone tamper reports an alarm to a monitoring station using Contact ID, the default event code is 137 for
“Tamper”. Should you require some zone group tampers to report a different code, you can change the event code
transmitted using these addresses.