Page 17
ACCESSING PROGRAM MODE FOR THE FIRST TIME
ACCESSING PROGRAM MODE FOR THE FIRST TIMEACCESSING PROGRAM MODE FOR THE FIRST TIME
ACCESSING PROGRAM MODE FOR THE FIRST TIME
GENERAL INFORMATION
There are two program modes in the panel. The first is the “Client” Program Mode to allow a system User to Add,
Change or Delete User Codes.
The second mode is the “Installer” Program Mode. The Installer Program Mode allows ALL programmed data to
be changed. Access to both Modes is described below.
ACCESS TO INSTALLER PROGRAM MODE ON POWER UP
When power is applied to the controller for the first time, (with the panel tamper input open and none of the
Areas either Armed or in Stay mode), the panel will inhibit tamper alarms and ready the panel to enter
INSTALLATION PROGRAM Mode (unless the Installer Lock-out option P741E4E has previously been enabled). At
this point you can go to any keypad which is connected to the panel and;
Press –”PROGRAM”-”ENTER”
This will automatically put the keypad into Installation Program mode. The LCD display will show “INSTALLER
MODE”.
ACCESS TO PROGRAM MODES FROM RUN MODE
Before you can enter program mode from the normal Run Mode, the panel must be disarmed and not in stay mode.
Then to access CLIENT MODE;
Press <PROGRAM> - <Code 1 (or Master Code)> - <ENTER>
LCD displays “CLIENT MODE”
Note: Default Master Code (Code 1) is 1,2,3
You are now in Client Program Mode. When you are in Client programming mode, the options set at P221E-P240E
define what areas of programming you may change.
To enter INSTALLER MODE from CLIENT MODE;
Press <PROGRAM> - <Install Code> - <ENTER>
LCD displays “INSTALLER MODE”
Note: Default Installer Code (P410E) is 0,0,0,0,0,0
By default the installer can go directly to Installer Program Mode from Normal Run mode provided No Areas are
Armed or in Stay Mode. The Installer Mode direct option can be disabled by turning Off Option 3 at address P741E.
HOW TO PROGRAM YOUR PANEL
Once you have accessed one of the Program Modes the programming sequence follows the example below;
<PROGRAM> - <1,2,3 or 4 digit address> - <ENTER>
3 short beeps if OK - 1 long beep if error
The LCD will display current value or status
Enter the new data
<New Data> - <ENTER>
3 short beeps if OK - 1 long beep if error
An example of programming is shown below. Here we are programming User Code 23 (P23E) with the code 2580.
P 23 E 2,5,8,0 E
In the example above the <P> represents the PROGRAM key, <23> represents the actual address for User Code
23, 2580 is the data and <E> represents the ENTER key.