P237E User Group #17 Miscellaneous Options - Default 5
P238E User Group #18 Miscellaneous Options - Default 5
P239E User Group #19 Miscellaneous Options - Default 5
P240E User Group #20 Miscellaneous Options - Default 5
Option 1 Can change telephone #’s - If this option is turned on, the User can enter Client Mode and change the
telephone numbers at addresses P830E-P836E.
Option 2 Can change Clock - If this option is turned on, the User can change the clock settings at addresses
P818E-P822E
Option 3 Can Print Event Memory - If this option is turned on, the User can access client mode and print the
memory events to a serial printer (if connected via the optional Serial Board). The User must enter
P1094E to start printing.
Option 4 Answer In-coming call or Start Callback - For security reasons, the panel may be set to not allow
automatic answering of an in-coming call. If this option is turned on however, the user can access Client
Mode while there is an in-coming call and press P1095E to make the panel answer the call (Answer In-
coming Call). Alternatively they can enter in P1108E and initiate a callback to the callback telephone
number. At this point Upload/download can occur.
Option 5 Can change Their Code - This option allows the User to access Client Mode to change their own code
but they cannot view or change any other codes.
Option 6 Can change All Codes - This option allows the User to access Client Mode to change any of the 100
User codes. If the User has this option assigned they can also start Walk-test Mode (P1096E) while in
Client Mode.
Option 7 Can allow access to Installer mode - This option allows the User to access Client Mode and then a
person with the Installer code can access Installer program Mode. If Direct access to installer mode is
turned off at address P741E option 3 then this is the only way to get into installer mode. If the User has
this option turned on they can also start Walk-test Mode (P1096E) and RSSI Mode (P710E & P720E)
while in Client Mode.
Option 8 Latchkey Arming - This option assigns the Latchkey Arming function to the User. If an Area is armed by
a Latchkey User (this option turned on) or by the “A” or “B” buttons with the Latchkey Arming function
assigned (see P812E & P813E option 5) the panel will arm in latchkey mode. If the panel is disarmed by
the same or another Latchkey user, nothing will happen. However, if the panel is armed in latchkey
mode and it is disarmed by a non-latchkey user (a user with this option turned off) the panel will send a
disarm report to a designated telephone number/s (as per the scenario programmed at P678E, P778E,
P878E & P978E). If the alarm is not armed by a Latchkey User no report will be generated on disarming.
This option is designed to allow a Latchkey User to arm the alarm and get a report when the children
have returned home and disarmed the alarm using their non-latchkey code.
USER
GROUPS 1-20 RADIO PENDANT OPTIONS P241E-P260E
P241E User Group #1 Radio Pendant Options - Default 0 OPTIONS
P242E User Group #2 Radio Pendant Options - Default 0 1 = Pendant Disabled in Alarm
P243E User Group #3 Radio Pendant Options - Default 0 2 = Immediate Panic Alarm
P244E User Group #4 Radio Pendant Options - Default 0 3 = Delayed Panic Alarm (1.5s)
P245E User Group #5 Radio Pendant Options - Default 0 4 = Spare
P246E User Group #6 Radio Pendant Options - Default 0 5 = Spare
P247E User Group #7 Radio Pendant Options - Default 0 6 = Spare
P248E User Group #8 Radio Pendant Options - Default 0 7 = Spare
P249E User Group #9 Radio Pendant Options - Default 0 8 = Spare
P250E User Group #10 Radio Pendant Options - Default 0
P251E User Group #11 Radio Pendant Options - Default 0
P252E User Group #12 Radio Pendant Options - Default 0
P253E User Group #13 Radio Pendant Options - Default 0
P254E User Group #14 Radio Pendant Options - Default 0
P255E User Group #15 Radio Pendant Options - Default 0
P256E User Group #16 Radio Pendant Options - Default 0
P257E User Group #17 Radio Pendant Options - Default 0
P258E User Group #18 Radio Pendant Options - Default 0
P259E User Group #19 Radio Pendant Options - Default 0