PROGRAMMING AREAS
PROGRAMMING AREAS PROGRAMMING AREAS
PROGRAMMING AREAS -
--
- Areas A,B,C & D
Areas A,B,C & D Areas A,B,C & D
Areas A,B,C & D
AREA "A" PRIMARY OUTPUT OPTIONS - P651E - P658E
AREA "B" PRIMARY OUTPUT OPTIONS - P751E - P758E
AREA "C" PRIMARY OUTPUT OPTIONS - P851E - P858E
AREA "D" PRIMARY OUTPUT OPTIONS - P951E - P958E
The addresses above allow a number Area based options to be assigned to any of the 8 outputs. Address P651
relates to Output 1 options for Area A, address P751 relates to Output 1 options for Area B, address P851 relates to
Output 1 options for Area C and address P951 relates to Output 1 options for Area D.
P651E 1 = Armed zone alarms to output #1
2 = Stay Mode alarms to output #1
3 = Pendant chirps to output #1
4 = All zones sealed indication to output #1
5 = 2 second pulse on arming or disarming to output #1
6 = Chime zone alarms to output #1
7 = Spare
8 = Spare
Option 1 Armed zone alarms to output #1 - This option will map zone alarms during the Armed state from Area
"A" to output #1.
Option 2 Stay Mode alarms to output #1 - This option will map alarms from zones defined as Area "A" Stay
Mode to output #1. Zones are defined as being in Stay Mode at addresses P411E-P430E option 5.
Option 3 Pendant Chirps to output #1 - This option will map one short pulse (Chirp) to output #1 when Area "A"
is armed via a radio key (Pendant) and two short pulses to output #1 when Area "A" is disarmed by a
radio key. The length of the pulses (Chirps) are set by the pulse timer (P921E) for this output.
Option 4 All zones sealed indication to output #1 - This option will map an Area "A" “Ready” indication to
output #1. The Output will be off (Ready) when all zones in the area are sealed.
Option 5 2 second pulse to output #1 on arming or disarming - This option will map a 2 second pulse to
Output #1 each time Area "A" is armed or disarmed as defined at P671E options 6&7.
Option 6 Chime zone alarms to output #1 - This option will map alarms from Area "A" zones defined as Chime
zones to output #1. Zones are programmed as Chime zones at P411E-P430E option 8. Chime zones
are those which normally operate only during periods when the Area is disarmed and are used as door
bells, shop minders, etc. A Chime zone will normally be part of the alarm when armed unless it is
programmed as a Permanent Chime zone at P431E-P450E option 4. A Permanent Chime zone will
always work as a Chime zone and will never cause an alarm when armed.
Note: P652E through P658E are as above but apply to outputs 2-8 for Area A
Note: P751E through P758E are as above but apply to outputs 1-8 for Area B
Note: P851E through P858E are as above but apply to outputs 1-8 for Area C
Note: P951E through P958E are as above but apply to outputs 1-8 for Area D
AREA "A" SECONDARY AREA OUTPUT OPTIONS - P661E - P668E
AREA "B" SECONDARY AREA OUTPUT OPTIONS - P761E - P768E
AREA "C" SECONDARY AREA OUTPUT OPTIONS - P861E - P868E
AREA "D" SECONDARY AREA OUTPUT OPTIONS - P961E - P968E
The addresses above allow a number of secondary Area based options to be assigned to any of the 8 outputs.
Address P661 relates to Output 1 options for Area A, address P761 relates to Output 1 options for Area B, address
P861 relates to Output 1 options for Area C and P961 relates to Output 1 options for Area D.
P661E 1 = Any Bypass to output #1
2 = Auto-Bypass warning to output #1
3 = Entry beeps to output #1
4 = Exit beeps to output #1