5 = Wrong Code Tamper Alarm to Output
6 = Radio Key Panic Alarm to Output
7 = 24 Hour Alarm to Output
8 = 24 Hour Fire Alarm to Output
Option 1 Keypad Panic to Output - This option is used to map the operation of the keypad panic to an output.
A keypad panic alarm is created by pressing the “PANIC”, “Chime” & “Control” or “1” & “3” buttons (the
correct option depends on the model of keypad used). See P788E-P790E for Panic Alarm options.
Option 2 Keypad Fire Alarm to Output - This option is used to map the operation of the keypad Fire Alarm to
an output. A keypad fire alarm is created by pressing the “A” & “B” or “4” & “6” buttons (the correct
option depends on the model of keypad used). See P791E for the Fire Alarm option.
Option 3 Keypad Medical Alarm to Output - This option is used to map the operation of the keypad Medical
Alarm to an output. A keypad medical alarm is created by pressing the “B” & “Chime” or “7” & “9”
buttons (the correct option depends on the model of keypad used). See P792E for the Medical Alarm
option.
Option 4 Duress Alarm to Output - This option is used to map a Duress Alarm to an output. A Duress Alarm is
generated when the alarm is unset by a valid user that adds the duress digit to the beginning of their
code. To reset the duress alarm to the output the area must be armed then disarmed.
Option 5 Wrong Code Tamper Alarm to Output - This option is used to map the Wrong Code Tamper Alarm
to an output. A Wrong Code Tamper Alarm is generated if an invalid code is entered more than 4 times
at a keypad. When the alarm is cleared using a valid code the output will be reset.
Option 6 Radio Key Panic Alarm to Output - This option is used to map the Radio Key Panic Alarm to an
output i.e. when the Radio Panic is generated any output with this option enabled will turn on.
Option 7 24 Hour Alarm to Output - This option is used to map 24 Hour Alarms to an output i.e. when a 24
Hour Alarm is generated any output with this option enabled will turn on.
Option 8 24 Hour Fire Alarm to Output - This option is used to map 24 Hour Fire Alarms to an output. When
the 24 Hour Fire Alarm is generated this will cause the output to flash at a rate set by the pulse timer
for this output to identify the difference between a fire alarm and normal burglar alarm.
SECONDARY ALARMS TO OUTPUT OPTIONS - P701E - P708E
In this block of addresses P701E relates to output #1, P702E relates to output #2 etc
P701E 1 = Zone Tamper Alarm to Output
2 = System Tamper Alarm to Output
3 = Mains Failure to Output
4 = Panel Battery Low to Output
5 = Telephone Line Failure to Output
6 = Dialler Kiss-off Failure to Output
7 = Automatic Pulse to Output
8 = 24 Hour Smoke Reset to Output
Option 1 Zone Tampers to Output - When a zone tamper alarm occurs this address is used to map the Zone
Tampers to an output.
Option 2 System Tamper Alarm to Output - This option is used to map a panel Tamper alarm to an output.
The tamper input is used to monitor the panel cabinet and satellite tamper switches.
Option 3 Mains Failure To Output - A mains failure will be indicated at the output when this option is enabled.
The Alarm Reset Timer (P901E) for this output should be set to “0”.
Option 4 Panel Battery Low to Output - A battery Low condition will be indicated at the output when this option
is enabled. The Alarm Reset Timer (P901E) for this output should be set to “0”.
Option 5 Telephone Line Failure to Output - A telephone line failure will be indicated at the output when this
option is enabled. The Alarm Reset Timer (P901E) for this output should be set to “0”.
Option 6 Dialler Kiss-off Failure to Output - If the dialler reaches its maximum dialling attempts and is not