AAP Elite S series Especificaciones Pagina 87

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 103
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 86
Page 87
Programming Area “D” Auto Arm/Disarm Time-zones
P969E Time Zones used for Area "D" auto arming /disarming- Default 0 (see P972E) Page 34
Area “D” Miscellaneous Options 1
P970E Misc area options 1 - Default 6 1 = Cannot Arm if not sealed Page 35
2 = “Arm” required before code
3 = “Stay” required before code
4 = Code required to arm
5 = Code required to “Bypass” zones
6 = Control/Chime disables chime zones
7 = Spare
8 = Cannot arm if Supervise fail active
Area “D” Miscellaneous Options 2
P971E Misc area options 2 - Default 0 1 = Near & Verified Alarms Page 36
2 = Spare
3 = Spare
4 = Pendant chirps when armed
5 = Pendant chirps when in Stay Mode
6 = 2 sec pulse at arm
7 = 2 sec pulse at disarm
8 = Cannot Arm if System Battery is Low
Area “D” Time & Delay Options
P972E AREA "D" TIME AND DELAY OPTIONS -Default 0 Page 36
1 = Arm area When Time Zone Ends
2 = Disarm area When Time Zone Starts
3 = Disable Stay Mode Exit Delay
4 = Disable Arm Mode Exit Delay
5 = Disable Stay Mode Entry Delay
6 = Disable Arm Mode Entry Delay
7 = Use special Stay Mode entry timer
8 = Report Stay Mode alarms & Bypasses via dialler
** Dialler Reporting Options for Area “D” **
P975E Area D reporting options -Default = 1 Page 37
1 = Send arm/disarm 5 = Send arm when exit delay expires (LED On)
2 = Send Stay Mode arm/disarm 6 = Send all zone restores at disarm only
3 = Send disarm only after activation's 7 = Spare
4 = Send Stay Mode disarm only after alarm 8 = Spare
** Area “D” Contact ID Account Code **
P976E Account number for Area "D" - default 0000 Page 38
**Area “D” Arm/Disarm Reporting Scenario **
P977E Area D Arm/Disarm reports mapped to scenario 1-4 default 1 Page 38
**Area “D” Latchkey Disarm Reporting Scenario **
P978E Area D Latchkey Disarm Reporting scenario 1-4 default 1 Page 38
Delays and Timers
P981E Area "A" exit delay - Default = 60 sec (0-999 sec) Page 49
P982E Area "B" exit delay - Default = 60 sec
P983E Area "C" exit delay - Default = 60 sec
P984E Area "D" exit delay - Default = 60 sec
P985E Area "A" Special Stay Mode entry delay - Default 20 sec (0-9999 sec) Page 49
P986E Area "B" Special Stay Mode entry delay - Default 20 sec
P987E Area "C" Special Stay Mode entry delay - Default 20 sec
P988E Area "D" Special Stay Mode entry delay - Default 20 sec
P989E Two trigger time period - Default 60 sec (0-999 sec) Page 49
Chime alarm to keypad and output timing
P991E Area "A" chime alarm keypad buzzer duration - Default 20 (0-999 in 1/10th sec steps) Page 50
P992E Area "B" chime alarm keypad buzzer duration - Default 20 (Default 20 = 2 seconds)
P993E Area "C" chime alarm keypad buzzer duration - Default 20
P994E Area "D" chime alarm keypad buzzer duration - Default 20
Vista de pagina 86
1 2 ... 82 83 84 85 86 87 88 89 90 91 92 ... 102 103

Comentarios a estos manuales