4 = Enabled Throughout the call in Disarm State only
5 = Enabled Throughout the call in Armed State only
6 = Enabled Throughout the call in Stay Mode State only
7 = Listen-in Enabled when the panel answers a call
8 = Hold Line Open after a Voice/Domestic Kiss-off.
P748E option 8 special function mode - If option 8 is turned on at address P748E, the dialler will delay hanging up
the call in Voice Mode following kiss-off and place the panel in DTMF remote control mode. The panel
will send the modem tones and look for DTMF remote control codes in the quiet period. If no DTMF
codes are received within 15 seconds the panel will hang-up. This option will NOT work if Option 8 at
P747E is turned on.
AUTO-ANSWER RING COUNT
P900E 1-99 Auto-Answer Rings - This option defines the number of rings before the panel will auto-answer
the incoming call.
MAINS FAIL REPORT DELAY
P909E 0-999 Mains (AC) Fail Report Delay - The panel, and expanders, are constantly checking that the
mains (AC) supply is present. If the mains supply fails, the dialler will delay reporting the failure for
the duration of the value programmed at this address. If the mains returns before this timer
expires the timer is reset and no mains fail event will be reported. A value from 0-999 seconds
can be programmed as the delay. A value of 0 will result in an instant report of mains failure.
ZONE ALARM REPORT DELAY
P910E 0-999 Report Delay on Zones - This delay pauses the reporting of zone alarms via the dialler for the
programmed period (0 = No delay). A value from 0-999 seconds can be programmed as the
delay. If the alarm is disarmed before this delay expires no alarms will be reported. The delay
pauses the reporting of zone alarms for all reporting formats. The delay can be used to prevent
false alarms from reporting if the user created an alarm on entry in error.
UPLOAD/DOWNLOAD SECURITY OPTIONS
P746E XXXXXXXX. Up to 8 digit security code for upload/download. The security code in the panel must
match that programmed into the PC before data transfer can occur.
P1095E Answer incoming call - provided a user who has option 4 turned on at addresses P221E-P240E
then enters in P1095E while in client program mode and the telephone line is currently ringing, the
panel will answer the incoming call and initiate an upload/download connection.