Programming Output On/Off Time Zone
P721E Output #1 Automatic on / off time zones - Default 0 (never) Page 43
P722E Output #2 Automatic on / off time zones - Default 0 (never)
P723E Output #3 Automatic on / off time zones - Default 0 (never)
P724E Output #4 Automatic on / off time zones - Default 0 (never)
P725E Output #5 Automatic on / off time zones - Default 0 (never)
P726E Output #6 Automatic on / off time zones - Default 0 (never)
P727E Output #7 Automatic on / off time zones - Default 0 (never)
P728E Output #8 Automatic on / off time zones - Default 0 (never)
Programming Output Enable Time Zones
P731E Output #1 Enable time zones - Default 0 (always) Page 43
P732E Output #2 Enable time zones - Default 0 (always)
P733E Output #3 Enable time zones - Default 0 (always)
P734E Output #4 Enable time zones - Default 0 (always)
P735E Output #5 Enable time zones - Default 0 (always)
P736E Output #6 Enable time zones - Default 0 (always)
P737E Output #7 Enable time zones - Default 0 (always)
P738E Output #8 Enable time zones - Default 0 (always)
Find Stored Radio Code Location
P740E Find Stored Radio Code Location Page 40
Miscellaneous System Options 1
P741E Misc Options 1 - Default 3,5 1 = Ignore Mains fail Page 44
2 = Ignore Zone Tampers during exit delay
3 = Installer code direct access
4 = Installer lockout
5 = System Tamper EOL (Off = Short circuit Tamper)
6 = Ignore expander Tamper Alarm
7 = Ignore Expander AC Fail
8 = Ignore Expander Comms fail
Miscellaneous System Options 2
P742E Misc Options 2 -Default = 0 1 = Sensorwatch Timer in Minutes Page 44
2 = KP Alarm Buzzer linked to OP1 Reset Time
3 = Memory Access Requires Code
4 = Send Output data to keypad buss (Off = No O/P data on buss)
5 = Output 1 is a siren output (8 ohm horn speaker)
6 = Inhibit Arming if “Radio Activity Failure” alarm active
7 = Test for RF Interference
8 = Installer Must Reset a System Tamper Alarm
Miscellaneous System Options 3
P743E Misc Options 3 -Default = None 1 = Enable Call-Back Only Mode Page 56
Programming Duress Digit
P744E Duress Digit (Value can be 1-9, 0 = disabled) default 0 Page 24
Programming Expander Fail Timeout
P745E PW32X Fail Timeout (16-999 seconds) default = 16 secs Page 45
** Upload/Download Security Code **
P746E XXXXXXXX. Up to 8 digit security code -Default = 0 Page 61
**Keypad Listen-in Options**
P747E Keypad Listen-in Options P747E Options (Default = 1-7 On) Page 60
1 = Enabled During Dialling in Disarm State only
2 = Enabled During Dialling in Armed State only
3 = Enabled During Dialling in Stay Mode State only
4 = Enabled Throughout the call in Disarm State only
5 = Enabled Throughout the call in Armed State only
6 = Enabled Throughout the call in Stay Mode State only
7 = Listen-in Enabled when the panel answers a call
8 = Delay hang-up on Voice Alarm kiss-off & turn on O/P 4