Page 32
P638E Zone Group #8 Vibration Sensitivity - Default 1
P639E Zone Group #9 Vibration Sensitivity - Default 1
P640E Zone Group #10 Vibration Sensitivity - Default 1
P641E Zone Group #11 Vibration Sensitivity - Default 1
P642E Zone Group #12 Vibration Sensitivity - Default 1
P643E Zone Group #13 Vibration Sensitivity - Default 1
P644E Zone Group #14 Vibration Sensitivity - Default 1
P645E Zone Group #15 Vibration Sensitivity - Default 1
P646E Zone Group #16 Vibration Sensitivity - Default 1
P647E Zone Group #17 Vibration Sensitivity - Default 1
P648E Zone Group #18 Vibration Sensitivity - Default 1
P649E Zone Group #19 Vibration Sensitivity - Default 1
P650E Zone Group #20 Vibration Sensitivity - Default 1
NORMAL ZONE RESPONSE TIME FOR THE HARDWIRED ZONES
.
P750E 1-31E. Default = 6
The Zone Response Time is the period that the zone input must be continuously unsealed before an alarm is
registered. The Response range is from approximately 50ms to 1.5 seconds. Setting the value to 1 will give a zone
response time of 50ms. Setting it to a value of 31 will give a zone response time of 1.5 seconds. Normally the default
value of 6 is satisfactory (approximately 300ms) but if required the time can be increased by programming a higher
number at this address. The maximum value allowed is a count of 31.