Page 20
P201E User Arm/Disarm Options for Group #1 - Default 1-8 OPTIONS
P202E User Arm/Disarm Options for Group #2 - Default 1,5,6 1 = Area "A"
P203E User Arm/Disarm Options for Group #3 - Default 1,5,6 2 = Area "B"
P204E User Arm/Disarm Options for Group #4 - Default 1,5,6 3 = Area "C"
P205E User Arm/Disarm Options for Group #5 - Default 1,5,6 4 = Area "D"
P206E User Arm/Disarm Options for Group #6 - Default 1,5,6 5 = Code can arm
P207E User Arm/Disarm Options for Group #7 - Default 1,5,6 6 = Code can disarm
P208E User Arm/Disarm Options for Group #8 - Default 1,5,6 7 = Code can arm stay mode
P209E User Arm/Disarm Options for Group #9 - Default 1,5,6 8 = Code can disarm stay mode
P210E User Arm/Disarm Options for Group #10 - Default 1,5,6
P211E User Arm/Disarm Options for Group #11 - Default 1,5,6
P212E User Arm/Disarm Options for Group #12 - Default 1,5,6
P213E User Arm/Disarm Options for Group #13 - Default 1,5,6
P214E User Arm/Disarm Options for Group #14 - Default 1,5,6
P215E User Arm/Disarm Options for Group #15 - Default 1,5,6
P216E User Arm/Disarm Options for Group #16 - Default 1,5,6
P217E User Arm/Disarm Options for Group #17 - Default 1,5,6
P218E User Arm/Disarm Options for Group #18 - Default 1,5,6
P219E User Arm/Disarm Options for Group #19 - Default 1,5,6
P220E User Arm/Disarm Options for Group #20 - Default 1,5,6
Option 1 Assigned to Area “A” - If this option is turned on, the User can Arm/Disarm Area “A” as programmed
by options 5, 6, 7, and 8.
Option 2 Assigned to Area “B” - If this option is turned on, the User can Arm/Disarm Area “B” as programmed
by options 5, 6, 7, and 8.
Option 3 Assigned to Area “C” - If this option is turned on, the User can Arm/Disarm Area “C” as programmed
by options 5, 6, 7, and 8.
Option 4 Assigned to Area “D” - If this option is turned on, the User can Arm/Disarm Area “D” as programmed
by options 5, 6, 7, and 8.
Option 5 User can ARM - If this option is turned on, the User can Arm ALL Areas assigned at options 1-4 above.
Option 6 User can DISARM - If this option is turned on, the User can Disarm ALL Areas assigned at options 1-4
above.
Option 7 User can ARM STAY Mode - If this option is turned on, the User can Arm Stay Mode for ALL Areas
assigned at options 1-4 above.
Option 8 User can DISARM STAY Mode - If this option is turned on, the User can Disarm Stay Mode for ALL
Areas assigned at options 1-4 above.
USER
GROUPS 1-20 MISCELLANEOUS OPTIONS P221E-P240E
The Miscellaneous User group options allow the User to gain access to Client Program Mode to perform various
program functions. If the User should not to have access to Client Mode, all options at this address must be off.
P221E User Group #1 Miscellaneous Options - Default 1-7 OPTIONS
P222E User Group #2 Miscellaneous Options - Default 5 1 = Can change telephone #’s
P223E User Group #3 Miscellaneous Options - Default 5 2 = Can change Clock
P224E User Group #4 Miscellaneous Options - Default 5 3 = Can Print Event Memory
P225E User Group #5 Miscellaneous Options - Default 5 4 = Answer In-coming call or Start Callback
P226E User Group #6 Miscellaneous Options - Default 5 5 = Can change Their Code
P227E User Group #7 Miscellaneous Options - Default 5 6 = Can change All Codes
P228E User Group #8 Miscellaneous Options - Default 5 7 = Allow access to Installer Mode
P229E User Group #9 Miscellaneous Options - Default 5 8 = Latchkey Arming
P230E User Group #10 Miscellaneous Options - Default 5
P231E User Group #11 Miscellaneous Options - Default 5
P232E User Group #12 Miscellaneous Options - Default 5
P233E User Group #13 Miscellaneous Options - Default 5
P234E User Group #14 Miscellaneous Options - Default 5
P235E User Group #15 Miscellaneous Options - Default 5
P236E User Group #16 Miscellaneous Options - Default 5
Comentarios a estos manuales