Option 2 Disarm area when the time zone starts - this option will automatically disarm area "A" when the time-
zone/s programmed at address P669E starts.
Option 3 Disable stay mode exit delay - If this option is on the exit delay for area "A" becomes “0” when arming
stay mode (the delay will still apply to full arm unless option 4 is also on).
Option 4 Disable arm mode exit delay - If this option is on the exit delay for area "A" becomes “0” when arming
the panel (the delay will still apply to stay mode unless option 3 is also on).
Option 5 Disable stay mode entry delay - If this option is on then all zones are instant in stay mode regardless
of any entry delays programmed to zones (entry delays will still apply to zones in full arm mode unless
option 6 is also on).
Option 6 Disable arm mode entry delay - If this option is on then all zones are instant in full arm mode
regardless of any entry delays programmed to zones (entry delays will still apply to zones in stay mode
unless option 5 is also on).
Option 7 Use special stay mode entry delay - If this option is on then all Area “A” Stay mode zones use the
special Stay Mode entry delay (P985E) in stay mode and the normal delays programmed at addresses
P531E-P550E are ignored. The normal delay will still apply during the normal Armed state.
Option 8 Send alarms and bypasses in stay mode - If this option is on then all alarms and zone bypasses in
Stay mode will be reported via the dialler in Contact ID. If the option is turned off, no alarm or bypasses
will be reported when using Stay Mode. Only zone alarms will be reported if using Domestic/ Voice or
Pager reporting formats. You should also note that if a Stay mode alarm is not kissed off in Domestic/
Voice or Pager mode and the alarm is not disarmed, when the dialler test time comes around, the
unreported zone alarms will report again. If this is not desired you can stop this from happening by
turning off all days for the test time at address P816E.
Note: P772E is the same as above but applies to Area B Time & Delay options
Note: P872E is the same as above but applies to Area C Time & Delay options
Note: P972E is the same as above but applies to Area D Time & Delay options
AREA “A” DIALLER REPORTING OPTIONS - P675E
AREA “B” DIALLER REPORTING OPTIONS - P775E
AREA “C” DIALLER REPORTING OPTIONS - P875E
AREA “D” DIALLER REPORTING OPTIONS - P975E
P675E 1 = Send Arm/Disarm
2 = Send Stay Mode Arm/Disarm
3 = Send Disarm only after activations
4 = Send Stay Disarm only after activations
5 = Send Arm at the end of the exit delay
6 = Send all zone restores when disarmed
7 = Spare
8 = Spare
Option 1 Send Arm/Disarm - If this option is on, the dialler will report Area "A" arms and disarms.
Option 2 Send Stay Mode Arm/Disarm - If this option is on, the dialler will report Area "A" stay mode arms and
disarms.
Option 3 Send Disarm only after activation - If this option is on, the dialler will report an Area A disarm following
an alarm activation. If there is no alarm, there will be no arm or disarm reports. This option is often used
in conjunction with alarm only reporting and stops the normal arm/disarm signals from being sent. If this
option is on it will override the option 1 setting.
Option 4 Send Stay Mode Disarm only after activation - If this option is on, the dialler will report an Area A Stay
Mode disarm following an alarm activation. If there is no alarm, there will be no Stay Mode arm or
disarm reports. This option is often used in conjunction with alarm only reporting and stops the normal
Stay Mode arm/disarm signals from being sent. If this option is on it will override the option 2 setting.
Option 5 Send Arm at the end of the exit delay - If this option is Off, the dialler will report an Arm immediately
the panel is armed. If the option is On, the Arm report is sent at the expiry of the exit delay. If the alarm
is disarmed before the exit delay expires, no Arm or Disarm signals will be sent.