DIALLER PROGRAMMING
DIALLER PROGRAMMINGDIALLER PROGRAMMING
DIALLER PROGRAMMING
ENABLING DIALLER & SETTING DIALLING PARAMETERS - P890E
P890E 1 = Enable dialler
2 = Fax defeat
3 = Disable line monitoring
4 = Pulse Dial
5 = Reverse Pulse Dial
6 = Report 24 Hr alarms in Domestic/Voice
7 = Auto-Detect Modem Format
8 = Force V21
Option 1 Enable Dialler - This option is used to enable the dialler. If this option is Off, all dialler reporting activity
will be disabled.
Option 2 Fax Defeat - This option enables fax defeat mode. When this option is turned on the panel will count the
incoming rings. If the number of rings is between 1-4 and then the ringing stops (call terminated), fax
defeat mode will be initiated. If another call is established within 45 seconds of termination of the first
call, the panel will answer on the first ring (fax defeat mode). If another call is not established within 45
seconds of the first call, the fax defeat mode is reset. For fax defeat to work the auto answer rings must
be enabled by putting in a suitably high ring count (e.g. 25).
Option 3 Disable Line Monitoring -If this option is turned on, the panel no longer tests the telephone line.
Option 4 Pulse Dial - If this option is turned on the dialler will use Pulse dialling. If the option is turned off the
dialler will use DTMF Dial. The default is set to DTMF dial.
Option 5 Reverse Pulse Dial - With this option off, the dialling pulses are normal i.e. a 1 = 1 pulse, a 9 = 9
pulses. If the option is on, then the pulses are reversed i.e. a 1 = 9 pulses, a 9 = 1 pulse. Note: this
option requires option 4 to be turned off to allow pulse dialling.
Option 6 Report 24 Hour alarms in Domestic/Voice Format - Normally 24 Hour alarms will not report via the
dialler in Domestic or Voice reporting formats. If 24 Hour alarm reporting is required for these formats
then they can be enabled by turning this option on.
Option 7 Auto-Detect Modem Format - The panel can connect using Bell103 or V21 formats when performing
upload/download connections. If this option is on, auto-detect is selected. In auto-detect mode the panel
generates the V21 tones first and if no connection is established it then generates the Bell103 tones. If
this option is turned off the format is fixed by the selection made at option 8.
Option 8 Force V21 Modem Format - If option 7 above is turned off then the modem format to be used for
upload/download is specified here. If this option is off the format is Bell103, if turned on the format is
V21.
REPORTING SCENARIOS - P892E - P895E
P892E 1-16E Reporting Scenario #1 options (Default=1, 7)
P893E 1-16E Reporting Scenario #2 options (Default = 0)
P894E 1-16E Reporting Scenario #3 options (Default = 0)
P895E 1-16E Reporting Scenario #4 options (Default = 0)
In order to provide the best flexibility when reporting alarms we have developed a unique system called "Reporting
Scenarios". The Scenarios define what action is taken by the panel for each alarm event, e.g. alternate between
numbers 1&2 until one is kissed-off or dual report to numbers 1&2 until both kissed-off. There are four individual
scenarios available each with up to 16 possible steps. The Scenarios consist of a string of digits that define the
reporting action to be taken by the panel. The digits in a Scenario are pre-defined. What the various digits are and
their meaning are listed in the following chart.