Option 11 Ness Protocol - If the wireless device is the Ness PIR then setting the option to 11 will allow the alarm
& 12 and battery low from the PIR to be processed correctly. If the device is the Ness wireless reed switch
then setting the option to 12 will allow the open/close & battery low signals to be processed correctly.
Option 31 Visonic K980W Protocol - If the wireless device is the Visonic K980W PIR then setting the option to 31
will allow the alarm/tamper & battery low signals to be received correctly.
Option 32 Powercode Protocol - If the wireless device is the Powercode PIR or wireless reed switch then
& 33 setting the option to 32 will allow the alarm/tamper & battery low signals plus the open & closed signal
from the reed switch to be received correctly but the supervised signal will be ignored. By setting the
option to 33, all signals from the Powercode PIR or Reed switch including the supervised signal will be
monitored correctly.
ZONE GROUP VOICE MESSAGE NUMBER
If you want the panel to play a custom voice message over the telephone when reporting a voice alarm then select
the message number at these addresses. The selected messages must first be pre-programmed into the optional
Voice Board. If the value is left at “0” the panel will not report any alarm messages for that zone group when set to
Voice Reporting. To enable reporting of these voice messages, “Speech Dialler” format must be selected for the
telephone number/s used (P837E-P842E Option 4). A value of 0-99 can be entered in these fields.
P511E Zone Group #1 Voice Message # - Default 0
P512E Zone Group #2 Voice Message # - Default 0
P513E Zone Group #3 Voice Message # - Default 0
P514E Zone Group #4 Voice Message # - Default 0
P515E Zone Group #5 Voice Message # - Default 0
P516E Zone Group #6 Voice Message # - Default 0
P517E Zone Group #7 Voice Message # - Default 0
P518E Zone Group #8 Voice Message # - Default 0
P519E Zone Group #9 Voice Message # - Default 0
P520E Zone Group #10 Voice Message # - Default 0
P521E Zone Group #11 Voice Message # - Default 0
P522E Zone Group #12 Voice Message # - Default 0
P523E Zone Group #13 Voice Message # - Default 0
P524E Zone Group #14 Voice Message # - Default 0
P525E Zone Group #15 Voice Message # - Default 0
P526E Zone Group #16 Voice Message # - Default 0
P527E Zone Group #17 Voice Message # - Default 0
P528E Zone Group #18 Voice Message # - Default 0
P529E Zone Group #19 Voice Message # - Default 0
P530E Zone Group #20 Voice Message # - Default 0
ZONE GROUP ENTRY DELAY TIME
This is the entry delay time all zones assigned with this group number will use when armed. If the alarm is disarmed
before the delay expires then no alarm will be generated. The delay also applies to 24 hour zones. A zero means
there is no entry delay. The range allowed is 0-9999 seconds.
P531E Zone Group #1 Entry Delay - Default 20
P532E Zone Group #2 Entry Delay - Default 0
P533E Zone Group #3 Entry Delay - Default 0
P534E Zone Group #4 Entry Delay - Default 0
P535E Zone Group #5 Entry Delay - Default 0
P536E Zone Group #6 Entry Delay - Default 0
P537E Zone Group #7 Entry Delay - Default 0
P538E Zone Group #8 Entry Delay - Default 0
P539E Zone Group #9 Entry Delay - Default 0
P540E Zone Group #10 Entry Delay - Default 0
P541E Zone Group #11 Entry Delay - Default 0
P542E Zone Group #12 Entry Delay - Default 0
P543E Zone Group #13 Entry Delay - Default 0
P544E Zone Group #14 Entry Delay - Default 0
P545E Zone Group #15 Entry Delay - Default 0
P546E Zone Group #16 Entry Delay - Default 0
P547E Zone Group #17 Entry Delay - Default 0