AREA "A" MISCELLANEOUS OPTIONS 2 - P671E
AREA "B" MISCELLANEOUS OPTIONS 2 - P771E
AREA "C" MISCELLANEOUS OPTIONS 2 - P871E
AREA "D" MISCELLANEOUS OPTIONS 2 - P971E
P671E 1 = Near & Verified Alarms
4 = Pendant chirps on Arm/Disarm
5 = Pendant chirps on Stay Mode Arm/Disarm
6 = 2 second pulse on Arm
7 = 2 second pulse on Disarm
8 = Cannot Arm if System Battery is Low
Option 1 Near & Verified Alarms - If this option is turned off the zone alarms for the area will report normally
(ie sending a 130 event code). If the option is turned on the panel will require two alarms on different
zones within a 45 minute period before a full alarm will be sent. If this option is turned on it applies to all
zones assigned to that area. An alarm on a single zone will send a CID (Contact ID) Near Alarm report
to the monitoring station. If no further alarms occur within 45 minutes (and the zone that activated is
sealed) the near alarm timer is reset and a restore is sent for the zone that activated. If the zone that
activated is still unsealed when the 45 minute timer expires, a zone bypass for that zone will be sent and
the zone will remain bypassed until the area is disarmed. Any new alarms after the timer has expired will
send another Near Alarm report. If a second alarm on a different zone occurs within 45 minutes of the
Near alarm, an Intrusion Verified alarm report will be sent. Turning this option on will stop zone alarms
from being reported in Domestic & Voice formats as there are no messages for near and confirmed
alarms. You must turn this option off if using Domestic or Voice formats.
Option 2&3 Spare -
Option 4 Pendant Chirps on Arm/Disarm - This option will send one short pulse (Chirp) to an output
programmed with option 3 on at P651E-P658E when Area "A" is armed via a radio key (Pendant) and
two short pulses to the output when Area "A" is disarmed by a radio key.
Option 5 Pendant Chirps on Stay Mode Arm/Disarm - This option will send one short pulse (Chirp) to an output
programmed with option 3 on at P651E-P658E when Stay Mode for Area "A" is armed with a radio key
(Pendant) and two short pulses to the output when Area "A" Stay Mode is disarmed by a radio key.
Option 6 2 second pulse on Arm - If this option is on, any output with option 5 on at addresses P651E-P658E
will turn on for 2 seconds when Area "A" is armed.
Option 7 2 second pulse on Disarm - If this option is on, any output with option 5 on at addresses P651E-P658E
will turn on for 2 seconds when Area "A" is disarmed.
Option 8 Cannot Arm if System Battery is Low - If this option is on, the Area cannot be armed if the system
Battery is Low. If the Option is off, the area may be armed even if the system Battery is Low.
Note: P771E is the same as above but applies to Area B Miscellaneous options 2
Note: P871E is the same as above but applies to Area C Miscellaneous options 2
Note: P971E is the same as above but applies to Area D Miscellaneous options 2
AREA "A" TIME AND DELAY OPTIONS - P672E
AREA "B" TIME AND DELAY OPTIONS - P772E
AREA "C" TIME AND DELAY OPTIONS - P872E
AREA "D" TIME AND DELAY OPTIONS - P972E
P672E 1 = Arm area when time zone ends
2 = Disarm area when time zone starts
3 = Disable stay mode exit delay
4 = Disable arm mode exit delay
5 = Disable stay mode entry delay
6 = Disable arm mode entry delay
7 = Use special stay mode entry delay
8 = Report alarms and bypasses in stay mode via Dialler
Option 1 Arm area when time zone ends - this option will automatically arm area "A" when the
time-zone/s programmed at address P669E ends.