Page 52
SETUP AND DIAGNOSTIC DATA
SETUP AND DIAGNOSTIC DATASETUP AND DIAGNOSTIC DATA
SETUP AND DIAGNOSTIC DATA
DYNAMIC DATA - P1090E-P1093E
These addresses are used to provide real time feedback from the panel as to the current status. They are intended
as view only addresses and only available in installer program mode.
P1090E Display keyboard address - Entering this program location will cause the panel to display the keypad
address (address 1-8).
P1091E Display Areas assigned to this keypad - Entering this program address will cause the keypad you are
using to display it's currently assigned Areas.
P1092E Display software version - Entering this program address will cause the keypad you are using to
display the panel software version number.
P1093E Active Time-Zones - If Time Zones are being used, by entering in this address while in Installation
Program Mode the panel will display any of the 8 time zones currently active. If 1-8 are On they indicate
active time zones.
START PRINTING THE EVENT BUFFER - P1094E
P1094E Start Event Printing - The alarm system stores the last 255 events in a non-volatile memory. Each
event has a time and date when the event occurred plus a description of the event. These events can be
printed to a serial printer if required. To print the events, a Serial Board must be plugged into the panel
(with the link set to printer on the serial board) and connected to a printer with an RS232 input. A user
with permission to print (e.g. P221E-P240E option 3 on) must enter client program mode (P-code-E),
then enter P1094E. The entire contents of the event buffer will be sent to the printer.
ANSWER AN IN-COMING CALL - P1095E
P1095E Answer an In-coming Call - For security reasons the installer may have programmed the panel so that
it can only answer an in-coming call if authorised by a user on-site. This would generally be used to
allow a PC connection to the panel. A user with permission to answer an in-coming call (e.g. P221E-
P240E option 4 on) must enter client program mode (P-code-E), then enter P1095E while the phone line
is ringing. The panel will then answer the call and allow the PC connection to be made.
START WALK TEST MODE - P1096E
P1096E Walk-test mode - When in Installation or Client Program mode, entering P1096E will turn On walk-test
mode. The keypad buzzer will beep at one second intervals to show that walk-test mode is active.
When in walk test mode the activated zone numbers will latch on at the keypad display. The Installer or
User can then walk past all of the detectors and return to the keypad to verify that they are functioning
correctly at the panel. The walk-test results are also stored in memory so they can be viewed at a later
time if required. Pressing any button will terminate walk-test mode and force the panel out of program
mode.
TEMPORARY OUTPUT DISABLE - P1097E
P1097E Temporary Output Disable - This address allows a technician to select any output/s to be temporarily
disabled for one alarm or armed cycle, e.g. by turning on 1-8 at P1097E then leaving program mode, the
selected outputs will not turn on following an alarm. The technician is now free to arm the system to test
all monitoring signals without having all of the internal & external alarms activating. When the alarm is
reset or disarmed all outputs will now work normally again.