OUTPUT PULSE TIMES - P921E to P928E
The pulse timer can be used to flash an output, control the duration of the radio arm/disarm chirps, etc. The
programmed value is in 1/10th of a second intervals, eg a programmed value of 2 = 2/10th sec (0.2sec),
a value of 10 = 1 sec, etc. The minimum duration is 0.2 seconds.
P921E 0-999 Output #1 pulse time -Default 0 (0 = Minimum 0.2 sec pulse)
P922E 0-999 Output #2 pulse time -Default 0 (0 = Minimum 0.2 sec pulse)
P923E 0-999 Output #3 pulse time -Default 0 (0 = Minimum 0.2 sec pulse)
P924E 0-999 Output #4 pulse time -Default 0 (0 = Minimum 0.2 sec pulse)
P925E 0-999 Output #5 pulse time -Default 0 (0 = Minimum 0.2 sec pulse)
P926E 0-999 Output #6 pulse time -Default 0 (0 = Minimum 0.2 sec pulse)
P927E 0-999 Output #7 pulse time -Default 0 (0 = Minimum 0.2 sec pulse)
P928E 0-999 Output #8 pulse time -Default 0 (0 = Minimum 0.2 sec pulse)
RADIO SIGNAL FAILURE TIMER - P929E
If this timer is set to “0”, no radio activity monitoring will occur. If it is set to any value other than “0”, the panel will be
checking to see that at least one of the programmed devices has been received within the timed period. Every time a
programmed radio detector is received, this timer is reset. If no signals have been received before this timer expires,
an alarm will be generated. The arming of the panel can also be inhibited if desired by turning on option 6 at address
P742E. This timer would normally only be used when supervised detectors are connected to the system.
P929E 0-255 Radio Signal Failure Timer (0-255 minutes) - Default 0
SENSORWATCH ALARM TIMER - P930E
If a zone group has the “Sensorwatch” option turned on (option 2 at addresses P451E-P470E), this timer sets the
monitoring period before a Sensorwatch alarm will occur. Every time a zone triggers at the panel, the Sensorwatch
timer for the zone is reset back to zero. If the time period expires, a Sensorwatch (zone inactivity) alarm will be
generated. The timer is stopped and the value saved when the area assigned to the zone group is armed. When the
area is disarmed the timer continues from the saved value. The default timer units is in hours but it can be
programmed to be in minutes at address P742E option 1.
P930E 0-255 Sensorwatch Timer (0-255 hours) - Default 120 hours
AREA EXIT DELAY TIMES - P981E to P984E
This is the exit delay time applicable to all zones in an area following arming. The alarm is only set when the exit
delay expires. Any zone can be unsealed during the exit delay but must be sealed when the delay expires.
P981E 0-999 Area "A" exit delay - 0-999 seconds - Default 60 seconds
P982E 0-999 Area "B" exit delay - 0-999 seconds - Default 60 seconds
P983E 0-999 Area "C" exit delay - 0-999 seconds - Default 60 seconds
P984E 0-999 Area "D" exit delay - 0-999 seconds - Default 60 seconds
SPECIAL STAY MODE ENTRY DELAY TIMES - P985E to P988E
If option 7 is turned on at addresses P672E, P772E, P872E & P972E, this entry delay time will apply to all Stay Mode
zones in that area. If option 7 is turned off, the entry delays programmed at P531E-P550E will apply.
P985E 0-999 Area "A" Special Stay Mode entry delay - Default 20 seconds
P986E 0-999 Area "B" Special Stay Mode entry delay - Default 20 seconds
P987E 0-999 Area "C" Special Stay Mode entry delay - Default 20 seconds
P988E 0-999 Area "D" Special Stay Mode entry delay - Default 20 seconds
TWO TRIGGER TIMER - P989E
If a zone group is set to two trigger (option 6 on at addresses P431E-P450E), zones in that group must activate twice
within the two trigger period to cause an alarm. A single zone can trigger twice or two separate zones trigger once
each within this time to create an alarm. If only one trigger is received before the two trigger timer expires, the timer is
reset and the process must be repeated. Also, if a single two trigger zone is left continuously un-sealed longer than
the two trigger time an alarm will be generated, eg a door with a reed switch that may have been forced and left
open..