Page 27
P467E Zone Group #17 Options C Default 1
P468E Zone Group #18 Options C Default 1
P469E Zone Group #19 Options C Default 1
P470E Zone Group #20 Options C Default 1
Option 1 Send Multiple reports via Dialler - A zone with this option turned on will send multiple alarm reports via
the dialler. If this option is off, the zone will only report one alarm per armed cycle. If the option “Send
Restores at disarm only” (option 6 at P675E, P775E, P875E & P975E) is turned on, this option must be
turned off for the function to work properly.
Option 2 Sensorwatch Zone - A zone with this option turned on will be monitored for Inactivity. Every time the
zone is triggered during the disarmed state the Sensorwatch timer for this zone will be reset to zero.
When the area that the zone is assigned to is armed, the Sensorwatch timer is stopped with the current
time saved. On disarming of the area, the Sensorwatch timer for the zone will resume with the value
saved when last armed. If the Sensorwatch time for the zone exceeds the programmed value at address
P930E an alarm will be generated. This option is designed to warn if a zone has not been operated for
sometime (possibly faulty or masked). The timer is normally in hours but can be set to minutes by
turning on option 1 at P742E.
Option 3 Soak Test Zone - A zone with this option turned on will be put into soak-test mode. In soak test mode
the zone cannot cause a normal alarm but any alarms when the system is armed will be recorded in the
event memory. This mode is designed to monitor problem zones without causing an alarm.
Option 4-7 Spare -
Option 8 Use second supervise timer # 2 - If this option is off, a supervised radio device will use the first
supervised timer # 1 (P919E). If the option is turned on, a supervised radio device will use supervise
timer # 2 (P920E). This is useful when detectors with different supervise transmission time periods are
used on the same system.
ZONE GROUP OPTIONS D - INPUT CONGIGURATION
Zone Options D
P471E Zone Group #1 Options D Default 1 1 = Zone is Hardwired
P472E Zone Group #2 Options D Default 1 2 = Zone uses 2k2 EOL resistor
P473E Zone Group #3 Options D Default 1 3 = Zone is monitored for Tamper
P474E Zone Group #4 Options D Default 1 4 = Zone is a Keyswitch
P475E Zone Group #5 Options D Default 1 5 = Keyswitch Arms the Area
P476E Zone Group #6 Options D Default 1 6 = Keyswitch is momentary
P477E Zone Group #7 Options D Default 1 7 = Zone uses NC contact
P478E Zone Group #8 Options D Default 1 8 = Zone is a Vibration detector
P479E Zone Group #9 Options D Default 1
P480E Zone Group #10 Options D Default 1
P481E Zone Group #11 Options D Default 1
P482E Zone Group #12 Options D Default 1
P483E Zone Group #13 Options D Default 1
P484E Zone Group #14 Options D Default 1
P485E Zone Group #15 Options D Default 1
P486E Zone Group #16 Options D Default 1
P487E Zone Group #17 Options D Default 1
P488E Zone Group #18 Options D Default 1
P489E Zone Group #19 Options D Default 1
P490E Zone Group #20 Options D Default 1
Option 1 Zone is Hardwired - If this option is turned on, the zone is hardwired. The panel will be looking for a
signal from an ELITE 32EX expander board. If the option is turned off, the zone is a radio zone. The
panel will be looking for a signal from a radio board. If set to hardwired (option 1 ON) the panel will not
allow radio zone learn mode (P680E) to run as the zone is not set to a radio type.
Option 2 Zone uses 2k2 EOL Resistor - If this option is turned on, the hardwired zone must have a 2k2 resistor
fitted to the zone input to seal the zone (type 2 input configuration on Page 6). If the option is turned off,
the input needs to see a short circuit to 0V to seal the input (type 1 input configuration on Page 6).
Option 3 Zone is Monitored for Tamper - If this option is turned on, the panel requires a 2k2 resistor to seal the
tamper and a 4k7 resistor is used for the zone (types 3 & 4 input configuration on Page 6). If the 2k2
resistor is shorted out or the input goes open circuit, a zone tamper will be generated. If the option is