Page 18
TO CLEAR PROGRAM INFORMATION (From Installation Mode Only)
If you wish to default the panel and start programming with a known set of parameters you can follow the sequence
below.
e.g. To reset ALL parameters to the factory settings
Press <PROGRAM> - 1105 - <ENTER>
1 beep
Then press - 1105 - <ENTER>
3 beeps
To ensure that the panel cannot be accidentally defaulted, the default address must be entered in twice as per the
example above before the default operation will occur.
TO EXIT PROGRAM MODES
To exit program modes when you have finished programming:
Press <PROGRAM> - <ENTER>
The panel is now back in normal Run Mode and any program changes you have made will be in effect.
Note: While in Program Mode, Tampers and 24 hour alarms are disabled which allows quiet access to the panel,
satellite siren units etc. Also, the panel cannot be armed while in program mode. On exiting program mode, all inputs
are scanned and if any tampers or 24Hr alarms are present an activation will occur.
Note: Where there are multiple options at one address, the numbers “0” & “9” have been reserved. Entering
a “0” at the address will turn all options OFF at that address whereas entering a “9” will turn all options ON
at that address.