directly by pressing the memory button. If it is turned on the Memory events can only be accessed after
pressing <MEMORY> then a valid code then <ENTER>.
Option 4 Send Output data to keypad buss - This option allows the output updates to the keypad buss for the
OUTPUTX4 board to be turned on if needed. If the option is On the Output data will be sent to the
keypad buss. It is normally turned off unless needed.
Option 5 Output 1 is a siren Output - Output 1 is normally an open drain high current FET output that switches
to 0V when activated. If this option is turned on Output 1 becomes a siren output designed to drive an 8
ohm horn speaker.
Option 6 Inhibit Arming if “Radio Activity Failure” alarm is active - If this option is off, the panel can be armed
even if no signals have been received from any programmed radio detectors within the preset period
programmed at address P929E. If this option is turned on, and no signals have been received from any
radio detectors for the programmed time set at P929E, the panel cannot be armed until a new
transmission is received. This option should only be used when supervised detectors are being used.
Option 7 Test for RF Interference - If this option is turned on the panel can automatically test the RSSI output of
the receiver to see if there is an excessive amount of RF activity. If there is more than 30 seconds of
received data within any 60 second period, the panel will display an “RF Fault” message and beep the
keypad buzzer if programmed to do so at address P804E. This feature should only be turned on if the
receiver fitted has the RSSI output.
Option 8 Installer Must Reset a System Tamper Alarm - If this option is off, the panel can still be used normally
if a system tamper alarm occurs. If the option is turned on, and a system tamper alarm occurs, the user
can reset the alarm but cannot Arm the system until the alarm is reset by an Installer. For the installer to
reset the “arm inhibit” function, they must enter Installer program mode via client program mode so the
installer direct access to program mode feature should be turned off (P741E Option 3) and the code
used to access client mode must have option 7 on at addresses P221E-P240E.
MISCELLANEOUS PANEL OPTIONS 3 - P743E
P743E 1 = Enable Callback Mode
2-8 = Spare
Option 1 Enable Callback Mode - For Security reasons the PC-Panel connection (upload/download) may require
the use of the Callback feature. This feature stops the panel from allowing an upload or download from a
PC unless the panel called the PC on the Callback number. If this option is turned on, Callback is the
only method of connecting with a PC. For the function to work there must be a Callback number
programmed at one of the telephone number locations and that number must have the Callback option
set (P837E-P842E).
EXPANDER FAIL TIMEOUT - P745E
Each expander connected to the panel sends a regular activity signal to show that it is still on-line. The signal is sent
approximately every 3 seconds. Every time an expander sends an on-line signal the timer at this address is reset. If
the timer expires due to a lack of on-line signals from an expander, a trouble alarm will be generated. This timer is
programmed in seconds and has a range of 16-999 seconds.
EXPANDERS CONNECTED TO THE PANEL - P749E
When you enter in address P749E the panel will tell you which expanders are connected. If number 1 is on it shows
that expander I is connected and working, if number 2 is on it shows that expander 2 is connected and working. If an
expander fails to communicate with the main panel or is temporarily removed for any reason the associated number
will be turned off at this location to indicate that it is currently not on-line. When an expander fails, the main panel will
generate and expander fail alarm and the trouble LED will turn on at the keypad. When the expander is back on-line
again the trouble LED will turn off and an expander restore will be generated. As soon as the expander board is back
on-line, the expander number will appear at this location again and main panel will start the expander fail timer
(P745E) for that expander board again. At power-up, if any hardwired zones are assigned to an expander board the
main panel will expect to get an on-line message from that expander. If it doesn’t get the on-line message an
expander fail will be generated. The fail alarm will be reset as soon as the expander is on-line.
P749E 1 = Expander 1 Active
2 = Expander 2 Active