Page 43
kissed off, this failure will be indicated at the output. When the Memory is viewed at a keypad the
output will reset back to normal. The Alarm Reset Timer (P901E) for this output should be set to “0”.
Option 7 Automatic Pulse to Output - This option will cause the output to pulse (at a rate set by the pulse timer
for the output) every 5 seconds. It is primarily designed to flash an external light to show that the alarm
is still active (reassurance indication).
Option 8 24 Hour Smoke Reset to Output - This option will cause the output to pulse for 2 seconds on arming
of any Area following a 24 Hour alarm. It is designed to allow automatic reset of hardwired latching
smoke detectors following an alarm. The output should be inverted so that it provides the 0V to power
the smoke detectors.
OUTPUT AUTO ON/OFF TIME ZONES - P721E - 728E
These addresses are used to map automatic ON and OFF periods to each of the outputs if required. When a time-
zone starts it will cause the output to turn on and when the time-zone ends it will cause the output to turn off. The
time-zones are programmed at addresses P1061E - P1084E. Multiple Time Zones may be assigned to each output.
P721E T/Z 1-8 Automatic On/Off Timezone/s for output #1
P722E T/Z 1-8 Automatic On/Off Timezone/s for output #2
P723E T/Z 1-8 Automatic On/Off Timezone/s for output #3
P724E - P728E As per the above but for outputs 4-8
NOTE: A value of zero (0) at these addresses will disable any auto turn on turn off features at that output.
OUTPUT ENABLE TIME ZONES - P731E - P738E
These addresses are used to map enable time-zones to each of the outputs as required. The assigned time-zone/s
will enable the output so that it can be used during the time-zone. If an output has a time-zone assigned and that
time-zone is currently inactive, the output cannot be turned on by any programmed function (the output is inhibited).
The time-zones are programmed at addresses P1061E - P1084E. This feature can be used to allow the audible
alarms to only occur at pre-determined times and days.
P731E T/Z 1-8 Enable On/Off Timezone/s for output #1
P732E T/Z 1-8 Enable On/Off Timezone/s for output #2
P733E T/Z 1-8 Enable On/Off Timezone/s for output #3
P734E - P738E As per above but for outputs 4-8
NOTE: A value of zero (0) at these addresses will enable the output at all times.